MIL-PRF-44015A(GL)
The fixture shall be supplied with a 100-watt 120-volt
incandescent light bulb.
3.2.8 Pilot light. The container shall be furnished with a
red vapor proof pilot light, located externally and protected
near the door which illuminates when the interior light switch is
in the "on" position.
3.2.9 Plug and receptacle. A weather-tight type receptacle,
recessed, male, locking type, designed for 3-wire, 2-pole
grounded service rated at 15 amperes, 125 volts, wired to the
interior light fixture and located in the rear on the exterior,
shall be provided. The plug provided shall form a weather-tight
joint when the plug is inserted in the receptacle. The plug
shall be captive to the container to prevent loss.
3.2.10 Temperature indicator. A Temperature indicator with a
range of -250F to +1250F shall be provided and installed on the
front exterior near the door. The sensing element shall be
mounted inside at a location that will provide a mean temperature
reading of the container. The Temperature Indicator and sensing
element shall be protected from damage by use of a guard or other
suitable protective device.
3.3 Interface and interoperability requirements. The
container units shall satisfy the following interface and
interoperability requirements.
3.3.1 Dimensions. Dimensions, tolerances and diagonal
differences of the container shall meet the requirements
specified in ISO 668 for type 1D containers , except the minimum
interior dimensions shall be 86 inches wide, 88 inches long and
83 inches in height.
3.3.2 Refrigerator interface. The end wall opposite the door
end wall shall have an opening as shown on figure 1 for mounting
a refrigeration unit. The end wall opening shall be of
sufficient strength to support the refrigeration unit having a
weight of 500 pounds. A plywood cover shall be provided when the
refrigeration unit is not in place. There shall be sufficient
space to mount an 18-inch deep refrigeration unit without the
unit protruding outside the corner fittings (see figure 1).
3.3.3 Padlock. The container shall be supplied with a
captive padlock conforming to ASTM F883 and shall be furnished
with two keys.
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business