MIL-PRF-13312R
more than 1300 pounds for type I units, excluding the battery and fuel, and not more than 1100
pounds for type II units.
3.4.2 Transportability. Refrigeration units shall be able to be lifted at the top of the unit to allow
loading and unloading for transport and operational setup.
3.4.3 Control panel. The refrigeration units shall have a control panel for the operator having, but
not limited to, the following items:
1.
Start, run, stop switch
2.
Operation indicator
3.
Refrigerator temperature control
4.
Refrigeration unit running time indicator
5.
Pressure reading indicators
6.
Refrigerator interior temperature indicator
7.
Defrost operation indicator
8.
Fuel capacity indicator for type I units
9.
Battery charging circuit voltage indicator for type I units
3.4.4 Service and maintenance. All major components shall be accessible for adjustment,
maintenance, servicing, and replacement without removing any other major component. All other
components and assemblies shall be designed for ease of installation and replacement and shall be
accessible for maintenance, repair, service and replacement with minimum disturbance to adjacent
components. No special tools shall be needed for any maintenance, repair, service, installation or
replacement action. Operator personnel shall be able to visually check the moisture content of the
refrigeration system on all refrigeration units and the compressor crankcase oil level on type I units.
3.4.5 Finish. The refrigeration units except where detrimental to proper operation shall have a
nontoxic chemical agent resistant green finish (see 6.7.1). The word "CARC", together with the
month and year of finishing, shall be stencilled near the identification plate in block letters not less
than 1 inch high using lusterless black chemical agent resistant paint (see 6.7.2) All paint shall be
properly applied .
3.4.6 Marking. Identification, instruction, control and gage plates shall be of corrosion-resistant
material permanently attached to the outside of the refrigeration unit. Numbering and lettering shall
be legible and permanently inscribed and shall be no less than 1/16 inch in height. All plates shall
blend with the framed enclosure finish and shall have a nonreflective surface.
3.4.6.1 Identification plate. The identification plate shall contain the following information:
5