MIL-PRF-44035B
3.2.11 Temperature control. The selected temperature of the
refrigeration units shall be controlled automatically. The
temperature control shall allow an incremental selection of
normal refrigerator/freezer temperatures. When temperature
settings selected are below 200F, the heating cycle shall not
operate.
3.2.12 Power requirements. Unless otherwise specified (see
6.2), the refrigeration units shall operate on 208/230 volt, 3-
phase, 60-hertz (Hz), and 200 volt, 3-phase, 50-Hz power.
3.2.12.1 Power supply cable. The unit shall be supplied with a
minimum 50-foot power supply cable capable of operating properly
with the power source and permanently attached to the outside of
the refrigeration unit. The cable shall have a quick-disconnect,
male-female fitting located at a minimum distance of 6 feet from
the refrigeration unit housing.
3.2.12.2 Lighting power supply cable. The refrigeration unit
shall be supplied with a minimum 36-foot SO type cable for 110
volt container lighting permanently attached to the outside of
the refrigeration unit.
3.2.13 Finish. The refrigeration units, except where
detrimental to proper operation, shall have a nontoxic chemical
agent resistant green finish (see 6.7.1). The word "CARC",
together with the month and year of finishing, shall be
stencilled near the identification plate in block letters not
less than 1 inch high using lusterless black chemical agent
resisting paint (see 6.7.2). All paint shall be properly
applied.
3.2.14 Safety. The refrigeration units shall minimize
flammability, operational and personnel hazards.
3.2.15 Airflow. The air exiting the evaporator shall be
directed to create proper circulation inside the refrigerator it
is used with.
3.3 Support or ownership requirements.
Refrigeration units
shall meet the following requirements.
3.3.1 Transportability. Refrigeration units shall be able to
be handled by a forklift truck and have devices allowing
personnel to position the unit.
3.3.2 Design reliability. Refrigeration units shall be
reliable and designed to operate without failure when subjected
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business