MIL-PRF-12574M
source for one 36-hour period of operation and on 3-phase, 50-Hz
power with voltage as specified in the contract for the other 36-
hour period.
4.3.2.10 Finish certification and examination . The contractor
shall certify that the refrigeration unit's finish is nontoxic and
chemical agent resistant, meeting government requirements. Painted
surfaces shall be visually examined to verify that there are no
streaks, crops, pinholes, checks or cracks.
4.3.2.11 Safety certification and inspection
.
Safety
requirements shall be verified as follows.
Wiring certification . Wiring practices used in the
4.3.2.11.1
refrigeration units shall be certified as conforming to NFPA
Standard No. 70 by submission of the manufacturer's certification, a
certified test report or appropriate labels or listing marks.
4.3.2.11.2.
Electrical components and enclosure certification
.
Electrical components shall be certified as conforming to the
requirements of UL Standard 486 and electrical enclosures (junction
boxes, control boxes, etc.) shall be certified as conforming to the
watertightness requirements of NEMA Standards Publication No. 250 by
submission of the manufacturer's certification, a certified test
report or appropriate labels or listing marks.
Refrigeration components certification . Refrigerant
4.3.2.11.3
containing components used in the refrigeration units shall be
certified as conforming to UL Standard 207 by submission of the
manufacturer's certification, a certified test report or appropriate
labels or listing marks.
4.3.2.11.4
Toxic hazards inspection . Visually inspect type I
refrigeration units to verify that provisions for oil drainage and
discharge of exhaust gases are located outside the refrigeration
unit.
4.3.2.11.5
Personnel safety inspection . Visually verify that a
plate indicating "Danger, Rotating Fan" has been permanently
attached on both sides of the condenser section when applicable.
4.3.3 Support or ownership requirements verification . All
ownership and support requirements shall be verified as follows.
4.3.3.1 Weight inspection . Verify, by weighing, that the type I
unit weighs no more than 775 pounds, excluding battery and fuel, and
15